Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40.706
Filtrar
1.
Eur Radiol Exp ; 8(1): 40, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38565836

RESUMO

BACKGROUND: To assess the feasibility and tissue response of using a gold nanoparticle (AuNP)-integrated silicone-covered self-expandable metal stent (SEMS) for local hyperthermia in a rat esophageal model. METHODS: The study involved 42 Sprague-Dawley rats. Initially, 6 animals were subjected to near-infrared (NIR) laser irradiation (power output from 0.2 to 2.4 W) to assess the in vitro heating characteristics of the AuNP-integrated SEMS immediately after its placement. The surface temperature of the stented esophagus was then measured using an infrared thermal camera before euthanizing the animals. Subsequently, the remaining 36 animals were randomly divided into 4 groups of 9 each. Groups A and B received AuNP-integrated SEMS, while groups C and D received conventional SEMS. On day 14, groups A and C underwent NIR laser irradiation at a power output of 1.6 W for 2 min. By days 15 (3 animals per group) or 28 (6 animals per group), all groups were euthanized for gross, histological, and immunohistochemical analysis. RESULTS: Under NIR laser irradiation, the surface temperature of the stented esophagus quickly increased to a steady-state level. The surface temperature of the stented esophagus increased proportionally with power outputs, being 47.3 ± 1.4 °C (mean ± standard deviation) at 1.6 W. Only group A attained full circumferential heating through all layers, from the epithelium to the muscularis propria, demonstrating marked apoptosis in these layers without noticeable necroptosis. CONCLUSIONS: Local hyperthermia using the AuNP-integrated silicone-covered SEMS was feasible and induced cell death through apoptosis in a rat esophageal model. RELEVANCE STATEMENT: A gold nanoparticle-integrated silicone-covered self-expanding metal stent has been developed to mediate local hyperthermia. This approach holds potential for irreversibly damaging cancer cells, improving the sensitivity of cancer cells to therapies, and triggering systemic anticancer immune responses. KEY POINTS: • A gold nanoparticle-integrated silicone-covered self-expanding metal stent was placed in the rat esophagus. • Upon near-infrared laser irradiation, this stent quickly increased the temperature of the stented esophagus. • Local hyperthermia using this stent was feasible and resulted in cell death through apoptosis.


Assuntos
Hipertermia Induzida , Nanopartículas Metálicas , Ratos , Animais , Ouro , Silicones , Estudos de Viabilidade , Ratos Sprague-Dawley , Esôfago , Stents
3.
J Biomed Opt ; 29(3): 036005, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560531

RESUMO

Significance: Color differences between healthy and diseased tissue in the gastrointestinal (GI) tract are detected visually by clinicians during white light endoscopy; however, the earliest signs of cancer are often just a slightly different shade of pink compared to healthy tissue making it hard to detect. Improving contrast in endoscopy is important for early detection of disease in the GI tract during routine screening and surveillance. Aim: We aim to target alternative colors for imaging to improve contrast using custom multispectral filter arrays (MSFAs) that could be deployed in an endoscopic "chip-on-tip" configuration. Approach: Using an open-source toolbox, Opti-MSFA, we examined the optimal design of MSFAs for early cancer detection in the GI tract. The toolbox was first extended to use additional classification models (k-nearest neighbor, support vector machine, and spectral angle mapper). Using input spectral data from published clinical trials examining the esophagus and colon, we optimized the design of MSFAs with three to nine different bands. Results: We examined the variation of the spectral and spatial classification accuracies as a function of the number of bands. The MSFA configurations tested showed good classification accuracies when compared to the full hyperspectral data available from the clinical spectra used in these studies. Conclusion: The ability to retain good classification accuracies with a reduced number of spectral bands could enable the future deployment of multispectral imaging in an endoscopic chip-on-tip configuration using simplified MSFA hardware. Further studies using an expanded clinical dataset are needed to confirm these findings.


Assuntos
Endoscopia Gastrointestinal , Neoplasias , Humanos , Diagnóstico por Imagem , Esôfago
4.
Wiad Lek ; 77(2): 241-246, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38592984

RESUMO

OBJECTIVE: Aim: To study the clinical anatomy of the pulmonary ligaments of young people. PATIENTS AND METHODS: Materials and Methods: The study was carried out when performing 28 autopsies of young people aged 25 to 44 years. Methods of dissection of chest organocomplexes, macro-microscopy, morphometry and planimetry, and statistical processing were used. The shape and topography of the pulmonary ligaments was assessed, their area, the localization of lymph nodes was examined. RESULTS: Results: The pulmonary ligament is an anatomical formation, which is formed as a result of a combination of leaves of the mediastinal pleura, which, covering the surfaces of the roots of the lungs, descend towards the diaphragm and are located between the mediastinal organs and the lungs. Pulmonary connections on both sides have a few edges: the inner, outer and lower free. The pulmonary ligaments with lower free edges do not pass to the diaphragmatic surface of the pleura, but only with inner ones, which are located on the right along the esophagus, and on the left along the aorta. Pulmonary ligaments on both sides pass into the mediastinal part of the pleura, covering the pericardium. CONCLUSION: Conclusions: There are individual differences between the shape and size of the right and left pulmonary ligaments in males and females. There is no significant difference between the sizes of the right and left pulmonary ligaments, but such dimensions as: the width, the angle of inclination and the ratio of their lower free edge to the lower edge of the lungs are not found in all cases.


Assuntos
Pulmão , Linfonodos , Masculino , Feminino , Humanos , Adolescente , Pulmão/anatomia & histologia , Esôfago , Pleura/anatomia & histologia , Autopsia
5.
J R Soc Interface ; 21(213): 20230592, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593841

RESUMO

The mechanical characterization of the oesophagus is essential for applications such as medical device design, surgical simulations and tissue engineering, as well as for investigating the organ's pathophysiology. However, the material response of the oesophagus has not been established ex vivo in regard to the more complex aspects of its mechanical behaviour using fresh, human tissue: as of yet, in the literature, only the hyperelastic response of the intact wall has been studied. Therefore, in this study, the layer-dependent, anisotropic, visco-hyperelastic behaviour of the human oesophagus was investigated through various mechanical tests. For this, cyclic tests, with increasing stretch levels, were conducted on the layers of the human oesophagus in the longitudinal and circumferential directions and at two different strain rates. Additionally, stress-relaxation tests on the oesophageal layers were carried out in both directions. Overall, the results show discrete properties in each layer and direction, highlighting the importance of treating the oesophagus as a multi-layered composite material with direction-dependent behaviour. Previously, the authors conducted layer-dependent cyclic experimentation on formalin-embalmed human oesophagi. A comparison between the fresh and embalmed tissue response was carried out and revealed surprising similarities in terms of anisotropy, strain-rate dependency, stress-softening and hysteresis, with the main difference between the two preservation states being the magnitude of these properties. As formalin fixation is known to notably affect the formation of cross-links between the collagen of biological materials, the differences may reveal the influence of cross-links on the mechanical behaviour of soft tissues.


Assuntos
Esôfago , Projetos de Pesquisa , Humanos , Estresse Mecânico , Esôfago/fisiologia , Anisotropia , Fenômenos Biomecânicos , Resistência à Tração
9.
BMC Pediatr ; 24(1): 246, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582899

RESUMO

BACKGROUND: Button battery (BB) ingestions (BBI) are increasingly prevalent in children and constitute a significant, potentially life-threatening health hazard, and thus a pediatric emergency. Ingested BBs are usually charged and can cause severe symptom within 2 h. Discharged BBs ingestion is very rare and protracted symptom trajectories complicate diagnosis. Timely imaging is all the more important. Discharged BBs pose specific hazards, such as impaction, and necessitate additional interventions. CASE PRESENTATION: We present the case of a previously healthy 19-month-old girl who was admitted to our pediatric university clinic in Germany for assessment of a three-month history of intermittent, mainly inspiratory stridor, snoring and feeding problems (swallowing, crying at the sight of food). The child's physical examination and vital signs were normal. Common infectious causes, such as bronchitis, were ruled out by normal lab results including normal infection parameters, negative serology for common respiratory viruses, and normal blood gas analysis, the absence of fever or pathological auscultation findings. The patient's history contained no evidence of an ingestion or aspiration event, no other red flags (e.g., traveling, contact to TBC). Considering this and with bronchoscopy being the gold standard for foreign body (FB) detection, an x-ray was initially deferred. A diagnostic bronchoscopy, performed to check for airway pathologies, revealed normal mucosal and anatomic findings, but a non-pulsatile bulge in the trachea. Subsequent esophagoscopy showed an undefined FB, lodged in the upper third of the otherwise intact esophagus. The FB was identified as a BB by a chest X-ray. Retrieval of the battery proved extremely difficult due to its wedged position and prolonged ingestion and required a two-stage procedure with consultation of Ear Nose Throat colleagues. Recurring stenosis and regurgitation required one-time esophageal bougienage during follow-up examinations. Since then, the child has been asymptomatic in the biannual endoscopic controls and is thriving satisfactorily. CONCLUSION: This case describes the rare and unusual case of a long-term ingested, discharged BB. It underscores the need for heightened vigilance among healthcare providers regarding the potential hazards posed by discharged BBIs in otherwise healthy children with newly, unexplained stridor and feeding problems. This case emphasizes the critical role of early diagnostic imaging and interdisciplinary interventions in ensuring timely management and preventing long-term complications associated even to discharged BBs.


Assuntos
Corpos Estranhos , Feminino , Humanos , Lactente , Ingestão de Alimentos , Esofagoscopia , Esôfago , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Sons Respiratórios/etiologia
10.
World J Gastroenterol ; 30(8): 984-990, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38516236

RESUMO

BACKGROUND: Cronkhite-Canada syndrome (CCS) is a rare, noninherited disease characterized by gastrointestinal polyposis with diarrhea and ectodermal abnormalities. CCS polyps are distributed through the whole digestive tract, and they are common in the stomach and colon but very uncommon in the esophagus. CASE SUMMARY: Here, we present a case of a 63-year-old man with skin hyperpigmentation accompanied by diarrhea, alopecia, and loss of his fingernails. Laboratory data indicated anemia, hypoalbuminemia, hypocalcemia, hypokalemia, and positive fecal occult blood. Endoscopy showed numerous polyps scattered throughout the digestive tract, including the esophagus. He was treated with nutritional support and glucocorticoids with remission of his symptoms. CONCLUSION: Comprehensive treatment led by hormonal therapy can result in partial or full remission of clinical symptoms. Treatment should be individualized for each patient according to their therapy response. Surveillance endoscopy is necessary for assessing mucosal disease activity and detecting malignant transformation.


Assuntos
Endoscopia Gastrointestinal , Polipose Intestinal , Masculino , Humanos , Pessoa de Meia-Idade , Endoscopia Gastrointestinal/efeitos adversos , Glucocorticoides/uso terapêutico , Esôfago/patologia , Polipose Intestinal/complicações , Polipose Intestinal/diagnóstico , Polipose Intestinal/terapia , Diarreia/etiologia
11.
Kyobu Geka ; 77(3): 217-221, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465495

RESUMO

A 51-year-old man visited to our hospital because of chest discomfort and hematemesis. He was diagnosed with Mallory-Weiss syndrome and followed in outpatient clinic. One week later, he visited our hospital again for fever and discomfort. Chest computed tomography (CT) showed a foreign body perforated in the mediastinum in the upper esophagus, and he was urgently hospitalized for surgical removal of esophageal foreign body. Before surgery he vomited the esophageal foreign body with a lot of blood. Hematemesis was stopped spontaneously and contrast-enhanced CT revealed a pseudoaneurysm in the distal aortic arch, so thoracic endovascular aortic repair (TEVAR) was performed to prevent rupture. Esophageal endoscopy found that the site of esophageal injury healed spontaneously, so the patient was followed conservatively with antibiotics. He was discharged on postoperative day 18 uneventfully. TEVAR was an effective treatment for aortic injury caused by esophageal foreign body in our case.


Assuntos
Doenças da Aorta , Procedimentos Endovasculares , Corpos Estranhos , Masculino , Humanos , Pessoa de Meia-Idade , Hematemese/complicações , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Doenças da Aorta/cirurgia , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia
13.
Lasers Surg Med ; 56(4): 392-403, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436122

RESUMO

BACKGROUND AND OBJECTIVES: Laser ablation is increasingly used to treat atrial fibrillation (AF). However, atrioesophageal injury remains a potentially serious complication. While proactive esophageal cooling (PEC) reduces esophageal injury during radiofrequency ablation, the effects of PEC during laser ablation have not previously been determined. We aimed to evaluate the protective effects of PEC during laser ablation of AF by means of a theoretical study based on computer modeling. METHODS: Three-dimensional mathematical models were built for 20 different cases including a fragment of atrial wall (myocardium), epicardial fat (adipose tissue), connective tissue, and esophageal wall. The esophagus was considered with and without PEC. Laser-tissue interaction was modeled using Beer-Lambert's law, Pennes' Bioheat equation was used to compute the resultant heating, and the Arrhenius equation was used to estimate the fraction of tissue damage (FOD), assuming a threshold of 63% to assess induced necrosis. We modeled laser irradiation power of 8.5 W over 20 s. Thermal simulations extended up to 250 s to account for thermal latency. RESULTS: PEC significantly altered the temperature distribution around the cooling device, resulting in lower temperatures (around 22°C less in the esophagus and 9°C in the atrial wall) compared to the case without PEC. This thermal reduction translated into the absence of transmural lesions in the esophagus. The esophagus was thermally damaged only in the cases without PEC and with a distance equal to or shorter than 3.5 mm between the esophagus and endocardium (inner boundary of the atrial wall). Furthermore, PEC demonstrated minimal impact on the lesion created across the atrial wall, either in terms of maximum temperature or FOD. CONCLUSIONS: PEC reduces the potential for esophageal injury without degrading the intended cardiac lesions for a variety of different tissue thicknesses. Thermal latency may influence lesion formation during laser ablation and may play a part in any collateral damage.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Terapia a Laser , Humanos , Esôfago/cirurgia , Esôfago/lesões , Esôfago/patologia , Átrios do Coração/cirurgia , Fibrilação Atrial/cirurgia , Lasers , Computadores , Ablação por Cateter/métodos
14.
Orphanet J Rare Dis ; 19(1): 114, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475835

RESUMO

BACKGROUND: In this study we aimed to describe the morphological and pathogenetic differences between tracheal agenesis and tracheal atresia, which are not clearly distinguished from each other in the literature, and to contribute thereby to the understanding and management of these conditions. Both tracheal agenesis and tracheal atresia represent rare disorders of still unknown aetiology that cannot be detected by prenatal ultrasound. If the affected foetuses survive until birth these conditions result in respiratory failure and in futile attempts to rescue the infant's life. RESULTS: Autopsies and genetic analyses, including singleton or trio exome sequencing, were performed on five neonates/foetuses with tracheal agenesis and three foetuses with tracheal atresia. Tracheal agenesis was characterized by absence of the sublaryngeal trachea and presence of a bronchooesophageal fistula and by pulmonary isomerism and occurred as an isolated malformation complex or as part of a VACTERL association. Special findings were an additional so-called 'pig bronchus' and a first case of tracheal agenesis with sirenomelia. Tracheal atresia presenting with partial obliteration of its lumen and persistence of a fibromuscular streak resulted in CHAOS. This condition was associated with normal lung lobulation and single, non-VACTERL type malformations. Trio ES revealed a novel variant of MAPK11 in one tracheal agenesis case. Its involvement in tracheooesophageal malformation is herein discussed, but remains hypothetical. CONCLUSION: Tracheal agenesis and tracheal atresia represent different disease entities in terms of morphology, pathogenesis and accompanying anomalies due to a primary developmental and secondary disruptive possibly vascular disturbance, respectively.


Assuntos
Deformidades Congênitas dos Membros , Traqueia/anormalidades , Recém-Nascido , Gravidez , Feminino , Humanos , Constrição Patológica , Esôfago/anormalidades
17.
Am J Case Rep ; 25: e942974, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38526305

RESUMO

BACKGROUND The VACTEREL association is an acronym that includes vertebral malformations (V), anal atresia (A), cardiac defects (C), tracheoesophageal fistula (TE), renal defects (R), and limb malformations (L). The aortic arch is the section between the ascending aorta and the descending aorta, where some variants have been described, such as the right aortic arch and bovine aortic arch, among others. A rare presentation in the Natsis classification is the "type X" where a bovine aortic arch and anomalous origin of the left vertebral artery are present. Several structural cardiac malformations have been described in the VACTEREL association. Still, there is no bovine arch or an anomalous left vertebral artery. CASE REPORT Our patient was a 3-year-old boy with a diagnosis of VACTEREL association (type III esophageal atresia, congenital hip dislocation, scoliosis, bilateral clubfoot, and grade IV biliary ureteral reflux). Echocardiographic findings showed changes in the aortic arch, and angiotomography and magnetic resonance angiography showed a bovine aortic arch and an anomalous left vertebral artery. At the time of diagnosis, there were no clinical manifestations or complications due to the anomalous origin of the left vertebral artery. CONCLUSIONS This is the first description of a bovine type X arch according to the Natsis classification in a VACTEREL association. In general, knowledge of the anatomical variants of the aortic arch and the origin and course of the vertebral arteries is of great clinical and interventional importance, mainly because of the risk of cerebral ischemia.


Assuntos
Canal Anal/anormalidades , Aorta Torácica , Esôfago/anormalidades , Cardiopatias Congênitas , Rim/anormalidades , Deformidades Congênitas dos Membros , Coluna Vertebral/anormalidades , Traqueia/anormalidades , Masculino , Humanos , Pré-Escolar , Aorta Torácica/diagnóstico por imagem , Artéria Vertebral , Aorta , Deformidades Congênitas dos Membros/diagnóstico por imagem
18.
J Math Biol ; 88(3): 37, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430250

RESUMO

This study discusses non-steady effects encountered in peristaltic flows in oesophagus. The purpose of this communication is to evolve a mechanism to diagnose tumor in an oesophagus mathematically. The tumor is modelled by generic bump function of certain height and width. The method of solution follows long wavelength and low-Reynolds number approximations for unsteady flow, while integrations have been performed numerically in order to plot graphs, which reveal various characteristics of the flow. The goal is to assess how pressure varies across the tumor's width. The spatial, as well as temporal, dependence of pressure has been studied in the laboratory frame of reference. The pressure distribution for tumor-infected oesophagus is compared with that of normal oesophagus. An intensified pressure is obtained in the presence of tumor. The interruption while swallowing through benign oesophageal tumor is confirmed by an abrupt pressure rise across the tumor's width. Tumor position also plays a significant role whether it is at contraction or relaxation of walls. Additionally, wall-shear-stress, volumetric flow rate and streamlines have also been described and compared with that without tumor growth. The expressions corresponding to all the physical quantities are computed numerically. Further, this model may also be implemented to the two-dimensional channel flow for an industrial application.


Assuntos
Deglutição , Neoplasias , Humanos , Modelos Teóricos , Esôfago , Peristaltismo
19.
J Emerg Med ; 66(4): e470-e476, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38461134

RESUMO

BACKGROUND: Tracheal intubation is the gold standard for airway management in emergency medicine, but more difficult to apply for inexperienced individuals than laryngeal mask airway (LMA). OBJECTIVE: The aim of our study was to investigate if inexperienced individuals are able to secure the airway with the help of LMA after a short introduction. A second aim was to evaluate Thiel-fixed specimens against unfixed ones. METHODS: In a body donor model, LMA application was evaluated between medical students without previous airway experience and anesthesiologists by comparing the sealing of the larynx using a water column applied to the esophagus. RESULTS: LMAs were successfully applied in 46 out of 55 (83.6%) attempts by medical students and in 30 out of 39 (76.9%) attempts by anesthesiologists. Among medical students, 14.1% of all LMA applications were primarily leaky, compared with 18.8% in anesthesiologists. Esophageal sealing was better in Thiel-fixed specimens (leakage 10.9%) compared with unfixed specimens (leakage 22.9%). Our data showed no significant difference between anesthesiologists and medical students in terms of sealing of LMA. Therefore, we conclude that medical students without previous airway experience can quickly learn to apply LMA sufficiently and thus, achieve aspiration protection similar to anesthesiologists. CONCLUSION: Medical students without previous airway experience can successfully insert LMAs after a short introduction. Thiel-fixed specimens are suitable for studies as well as for training in LMA application.


Assuntos
Máscaras Laríngeas , Humanos , Anestesiologistas , Intubação Intratraqueal , Manuseio das Vias Aéreas , Esôfago
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...